Device for measuring illuminance, luminance, PAR, irradiance. Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree. Complete with carrying case, instruction manual, 3 batteries. LP471. series probes with SICRAM module are suitable. The probes have to be ordered separately, possibilites are:

LP471UVA Radiometric probe for measuring the IRRADIANCE in the UVA spectral range 315nm…400nm, peak at 360nm, quartz diffuser for cosine correction. Measuring range: 0.1 mW/m2 … 2000 W/m2.

LP471UVB Radiometric probe for measuring the IRRADIANCE in the UVB spectral range 280nm…315nm, peak at 305nm, quartz diffuser for cosine correction. Measuring range: 0.1 mW/m2 … 2000 W/m2.

LP471UVC Radiometric probe for measuring the IRRADIANCE in the UVC spectral range 220nm…280nm, peak at 260nm, quartz diffuser for cosine correction. Measuring range: 0.1 mW/m2 … 2000 W/m2.

LP471LUM 2 Photometric probe for measuring the LUMINANCE, spectral response according to the photopic curve, angular field 2°. Measuring range: 0.1 cd/m2 … 2000·103 cd/m2. 2m cable.

LP471ERY Radiometric probe for measuring the TOTAL EFFECTIVE IRRADIANCE, spectral range: 250nm…400nm, quartz diffuser for cosine correction. Measuring range: 0.1x 10 -3 Weff /m2…2000 Weff /m2. Cable length 2m.

LP471P-A
Combined probe for measuring the ILLUMINANCE (lux), with standard photopic spectral response, and for measuring
the IRRADIANCE (W/m2) in the UVA spectral range (315-400 nm, with peak at 365 nm). Both sensors are equipped
with diffuser for the correction according to the cosine law. Illuminance measuring range: 0.3 lux … 200⋅103 lux.
Irradiance measuring range: 0.1 mW/m2…2000 W/m2. The probe provides the ratio of the UVA irradiance and the
illuminance in μW/lumen (quantity of interest in the museums field). Supplied with SICRAM module and 2 m cable.

LP471A-UVeff
Combined probe for measuring the TOTAL EFFECTIVE IRRADIANCE according to the weighting curve UV. The
two sensors are used to correctly measure the total effective irradiance in the range 250-400 nm. Both sensors are
equipped with diffuser for the correction according to the cosine law. The probe provides the total effective irradiance
(Eeff), the effective irradiance in the range UV-CB and the UVA irradiance. Total effective irradiance measuring range:
0.001 W/m2…20 W/m2. B_C effective irradiance measuring range: 0.001 W/m2…20 W/m2. UVA irradiance measuring
range: 0.1 W/m2…2000 W/m2. Supplied with SICRAM module and 2 m cable.

LP471SILICONPYRA
Pyranometer with silicon photodiode to measure the GLOBAL SOLAR IRRADIANCE, diffuser for cosine correction.
Spectral range: 400…1100 nm. Measuring range: 0…2000 W/m2. Fixed cable 5m long, with SICRAM module. The
probe can be connected to the instruments DO9847, HD2302.0, HD2102.1 and HD2102.2

LP47 PYRA03.5 Probe consisting of a second class pyranometer LP PYRA 03 and a 5m long cable complete with SICRAM module. The calibration report of the pyranometer connected to the cable with SICRAM module is included. The probe can be connected to the instruments DO9847, HD2302.0, HD2102.1 and HD2102.2

LP471PYRA 03.10 Probe consisting of a second class pyranometer LP PYRA 03 and a 10m long cable complete with SICRAM module.
The calibration report of the pyranometer connected to the cable with SICRAM module is included. The probe can be
connected to the instruments DO9847, HD2302.0, HD2102.1 and HD2102.2

LP471PYRA02.5 Probe consisting of a first class pyranometer LP PYRA 02 and a 5m long cable complete with SICRAM module. The calibration report of the pyranometer connected to the cable with SICRAM module is included. The probe can be connected to the instruments DO9847, HD2302.0, HD2102.1 and HD2102.2

LP471PYRA02.10 Probe consisting of a first class pyranometer LP PYRA 02 and a 10m long cable complete with SICRAM module. The calibration report of the pyranometer connected to the cable with SICRAM module is included. The probe can be connected to the instruments DO9847, HD2302.0, HD2102.1 and HD2102.2